PLZ-5W/5WZ_EXT CONT connector

ModelPLZ205WPLZ405WPLZ1205W
Load on/off control inputLogic level switchable. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V.
Range control inputThe range can be switched between L, M, and H using a 2 bit signal. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V.
Alarm inputAn alarm is activated with a voltage between 0 V and 1.5 V. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5 V, LOW: 0 V to 1.5 V.
Alarm clearing inputAfter an alarm occurs, eliminate the root cause of the alarm, and change the input to pin 5 of the EXT CONT connector from a low level signal to a high level signal. The alarm will be cleared on the rising edge of this signal. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 3.5 V to 5.0 V, LOW: 0 V to 1.5 V.
Trigger inputPaused sequence operation resumes when a voltage between 0 V and 0.8 V is received. Pulled up to 5 V by a 10 kΩ resistor. The thresholds are HIGH: 2 V to 5 V, LOW: 0 V to 0.8 V.
External voltage control input (CC, CR, CP mode) Controls the load settings of CC, CR, CP mode through external voltage input. The input impedance is approx. 10 kΩ. CC: The setting can be controlled in the range of 0% to 100% of the rated current through external voltage input of 0 V to 10 V. CR: The setting can be controlled in the range of 0% to 100% of the conductance setting through external voltage input of 0 V to 10 V. CP: The setting can be controlled in the range of 0% to 100% of the rated power through external voltage input of 0 V to 10 V.
Setting accuracy± (1% of range) (TYP value of H range in CC mode)
External voltage control input (CV mode) The load setting of CV mode can be controlled through external voltage input. The rated voltage can be controlled in the range of 0% to 100% with 0 V to 10 V. The input impedance is approx. 10 kΩ.
Setting accuracy± (1% of range) (TYP value)
External voltage control input (superimposing in CC mode) Controls the load setting of CC mode by adding current through external voltage input. Adds current in the range of -100% to 100% of the rated current for -10 V to 10 V. The input impedance is approx. 10 kΩ.
Setting accuracy± (1% of range) (TYP value of H range)
Load-on status outputOn when load is on. Open-collector output from a photocoupler. *1
Range status outputOutputs current range state L, M, and H using 2 bits. Open-collector output from a photocoupler. *1
ALARM 1 outputTurns on when overvoltage detection, reverse-connection detection, overheat detection, alarm input detection, front-panel load input terminal overcurrent detection, or parallel operation anomaly detection is activated. Open-collector output from a photocoupler. *1
ALARM 2 outputTurns on when OCP, OPP, UVP, or WDP is activated.
DIGITAL 0 / DIGITAL 1 outputLogic signal output during a step of a sequence. Output impedance: approx. 330 Ω, output voltage: approx. 3.3 VEMF
DIGITAL 2 outputInput/output switchable. Output: Logic signal output during a step of a sequence. The output impedance is 330 Ω.Input: Trigger input signal for the sequence and the measurement functions. The thresholds are HIGH: 2 V to 5 V, LOW: 0 V to 0.8 V.
Current monitor output Outputs 0 V to 10 V for 0% to 100% of the rated current of each range.
Accuracy± (1% of range) (TYP value of H range)
Short signal outputRelay contact turns on when the short function is turned on (30 Vdc/1 A).

*1 The maximum voltage that can be applied to the photocoupler is 30 V. The maximum current is 4 mA.