27804

PXZ_Protection Specifications HIGH alarm

An alarm requiring a reboot to be cleared.

ItemCommon to all models
Reverse Alarm (Reverse-connection detection protection)Protective operationLoad off, indicate “REVE” on the display
OHP (Overheat protection)Protective operationLoad off, indicate “OHP” on the display. SLV OHP is displayed on the slave unit.
Line OVP (Grid overvoltage protection)Protective operationLoad off, indicate “LOVP” on the display. SLV LOVP is displayed on the slave unit.
Setting rangeInput voltage rating 200 Vac model: 200 V to 258 V
Input voltage rating 400 Vac model: 380 V to 516 V
Line UVP (Grid undervoltage protection)Protective operationLoad off, indicate “LUVP” on the display. SLV LUVP is displayed on the slave unit.
Setting rangeInput voltage rating 200 Vac model: 175 V or less.
Input voltage rating 400 Vac model: 333 V or less.
Line Frequency Error (Grid abnormal frequency protection)Protective operationLoad off, indicate “FREQ” on the display. SLV FREQ is displayed on the slave unit.
Detection value42 Hz/68 Hz
External Alarm HIGH Level (External input alarm detection)Protective operationLoad off, indicate “EXT HIGH” on the display
SENS Alarm (incorrect sensing connection detection)Protective operationLoad off, indicate “SENS” on the display
Setting rangeEnable/Disable
Parallel Communication Error (Parallel operation communication error detected)Protective operationLoad off, indicate “PARA COM” on the display
Para Other Slave Alarm (Parallel operation slave error occurred)Protective operationLoad off, indicate “SLV OTHR” on the display
Incorrect Slave Alarm (Not applicable device connected)Protective operationLoad off, indicate “SLV INC” on the display
Too many connections (Too many parallel connections)Protective operationLoad off, indicate “TOO MANY” on the display
Hardware ERR*1 (Hardware error)Protective operationLoad off, indicate “ERRH” on the display. SLV ERRH is displayed on the slave unit.
Software ERR*2 (Software error)Protective operationLoad off, indicate “ERRS” on the display. SLV ERRS is displayed on the slave unit.

*1 It occurs when an abnormality related to the software is detected and the internal unit comes to an emergency stop. *2 It occurs when an abnormality related to the software is detected and the internal unit comes to an emergency stop.