27804

PXZ_General Specifications

ItemPXZ20K-500PXZ20K-1000PXZ20K-1500
WeightApprox. 38 kg (83.78 lbs)Approx. 37 kg (81.57 lbs)Approx. 37 kg (81.57 lbs)
Dimensions430 (16.93)(MAX455 (17.91))W × 128 (5.04)(MAX160 (6.30))H × 720 (28.35)(MAX980 (38.58))D mm (inches)
Refer to Outline Drawing
Environmental conditionsOperating environmentIndoor use, overvoltage category II
Operating temperature0 °C to +50 °C (32 °F to +122 °F)
Operating humidity20 %rh to 85 %rh (no condensation)
Storage temperature-25 °C to +60 °C (-13 °F to +140 °F)
Storage humidity90 % rh or less (no condensation)
AltitudeUp to 2000 m
Cooling systemForced air cooling using fan
AccessoriesAC INPUT terminal cover, External control connector kit (1 set), Chassis connection wire, DC INPUT terminal cover, DC INPUT terminal screws (1 pair), EXT SYNC connector cover, SENSING connector cover, SENSING connector (2 pc.), Synchronized operation signal cable kit, Safety Information (1 copy), China RoHS sheet (1 sheet), Getting Started Guide (1 copy), Heavy object warning label (1 piece)
Withstanding voltageBetween primary and FG2200 Vac for 1 minute
Between primary and secondary
Between secondary and FG1800 Vdc for 1 minute1800 Vdc for 1 minute3000 Vdc for 1 minute
Insulation resistanceBetween primary and FG30 MΩ, 500 Vdc
Between primary and secondary30 MΩ, 1000 Vdc
Isolation voltage±1000V±1000V+2000V/-1000V
Electromagnetic compatibility (EMC)*1*2Conforms to the requirements of the following standard.
EMC Directive 2014/30/EU
EN 61326-1 (Class A*3)
Safety*1Conforms to the requirements of the following standard.
Low Voltage Directive 2014/35/EU*2
EN 61010-1 (Class I*4, Overvoltage category II, Pollution Degree 2*5)

*1 Does not apply to specially ordered or modified products. *2 Only for models with CE marking / UKCA marking on their body. *3 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *4 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded. *5 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.