27804

PXZ_Constant current (CC) mode

ItemPXZ20K-500PXZ20K-1000PXZ20K-1500
Maximum settable current *1+126 A+63A+31.5 A
Setting accuracy*2±(0.75 % of rating)
Resolution0.01 A0.005A0.002 A
Line regulation *3±240 mA±120mA±60 mA
Load regulation *4±240 mA±120mA±60 mA
Rise time(TYP)*51 ms
Fall time (TYP)*61 ms
Response switchingFAST, SLOW
Slew rate switching *1120A/ms or more *760A/ms or more *730A/ms or more *7
60 A/ms30 A/ms15 A/ms
30 A/ms15.0A/ms7.5 A/ms
3 A/ms1.50A/ms0.75 A/ms
0.3 A/ms0.150A/ms0.075 A/ms

*1. During parallel operation, this will be the value multiplied by the number of units in the configuration. *2. Applies to a range of 1 % to 100 % of the rated current. *3. 180 Vac to 252 Vac for 200 Vac input, 342 Vac to 504 Vac for 400 Vac input. At the constant load. *4. This is the amount of change when the voltage is changed from the rated voltage and rated power to 1/10 of the rated voltage. *5. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 10 % to 90 % of the rated current when the input current
value is changed from 0 % to 100 % of the rated current. When the slew rate is set to MAX. *6. In the case that the CC mode response setting is set to FAST. The time required for the input current in CC mode to change from 90 % to 10 % of the rated current when the input current
value is changed from 100 % to 0 % of the rated current. When the slew rate is set to MAX. *7. MAX will appear on the display.


Related specifications : PXZシリーズ

Please feel free to contact us with any questions or concerns.

Download a Product CatalogView List
Request a QuotationContact Us