ModelSingle-phase outputSingle-phase/three-phase switchable model
  PCR1000WEAPCR2000WEAPCR3000WEA2PCR6000WEA2PCR12000WEA2PCR18000WEA2PCR24000WEA2PCR30000WEA2PCR36000WEA2
  PCR6000WEA2RPCR12000WEA2RPCR18000WEA2RPCR24000WEA2RPCR30000WEA2RPCR36000WEA2R
Voltage Rms valueResolution0.1 V
Accuracy *1DC, 40 Hz to 999.9 Hz : ±(0.3 % of reading +1 V), 1 kHz to 5 kHz : ±(0.5 % of reading +1 V)
Current Rms valueResolution0 to 99.99 A: 0.01 A, 100 to 999.9 A: 0.1 A
Accuracy *1 *245 Hz to 65 Hz : ±(0.3 % of reading +0.3 % of f.s) DC, 40 Hz to 999.9 Hz : ±(0.6 % of reading +0.6 % of f.s)
1 kHz to 5 kHz : ±(1.2 % of reading +1.2 % of f.s)
Current peak valueResolution0 to 99.99 A: 0.01 A, 100 to 999.9 A: 0.1 A
Accuracy *1 *34 % of f.s
Active powerResolution1 W *5
Accuracy *1 *2 *445 Hz to 65 Hz : ±(0.3 % of reading +0.3 % of f.s)
Apparent powerResolution1 VA *6
Apparent powerResolution0.01
Power factorResolution0.1°
Harmonic measurementFrequency range (fundamental wave)10 Hz to 1 kHz
Upper limit of harmonic analysis5th to 50th
FFT data length4096
Measurement itemsRms voltage and current, phase angle, THD
Recommended calibration period1 year

* 1 At ambient temperature of 23 °C±5 °C. * 2 At 10 % to 100 % of maximum rated current, sine wave. * 3 Pulse height of sine wave * 4 At a power factor of 1. * 5 When the measured value is 0 to less than 100 W, the resolution is 0.1 W. *6 When the measured value is 0 to less than 100 VA, the resolution is 0.1 VA.