How can I control the output on/off via the external contact of the J3 connector in PAV series?

a) Set ILC to ON from the MENU key.
b) Set the start mode to auto start.
c) Short-circuit between J3-4 and J3-7 so that the external contact is on.
e) Turn the output on with the OUTPUT key on the panel once.
Then, the output on/off control via the external contact is available.
When the output is off (open between J3-4 and J3-7), the voltmeter shows “EnA” with no ammeter display and the ALARM LED blinks in red, the output on/off control is working correctly.
If the panel shows OFF instead of “EnA”, check the above settings, and turn the output on with the OUTPUT key.
For the details, read the user’s manual – chapter of External Control – Output on/off control (ILC).