Item | Specifications | |||
---|---|---|---|---|
Overvoltage (overcharge) protection | ||||
Software OVP | Setting range | 0.000 V to 6.300 V | ||
Resolution | 1mV | |||
Setting accuracy *1 | Depends on the voltmeter accuracy | |||
Operating time | 50 ms max. | |||
Hardware OVP *2 | Setting range | 0.0 V to 6.6 V | ||
Resolution | 100mV | |||
Setting error *1 | ±0.5% of rating | |||
Operating time | 10 ms (TYP) From overvoltage detection to output shutoff. |