Item | Specifications | |||
---|---|---|---|---|
Software OCP | Operating range | Charge | 2A range | 0.000 A to 2.100 A |
20A range | 0.000 A to 21.000 A | |||
Discharge | 2A range | 0.000 A to 2.100 A | ||
20A range | 0.000 A to 21.000 A | |||
Resolution*3 | 1mA | |||
Setting accuracy *1 | Depends on the ammeter accuracy | |||
Operating time | 50 ms max. | |||
Delay time | 0 ms min. Detection delay timer setting | |||
Hardware OCP *2 | Operating range | Charge/ discharge | 2A range | 0.0 A to 2.2 A |
20A range | 0.0 A to 22.0 A | |||
Resolution*3 | 100mA | |||
Setting error *1 | ±0.5% of rating | |||
Operating time | 10 ms(TYP) From overcurrent detection to output off. |