Item | Specifications | |
---|---|---|
Nominal input rating | 200 Vac to 240 Vac, 50 Hz / 60 Hz, single phase | |
Input voltage range | 180 Vac to 250 Vac | |
Maximum power consumption | 1870 VAmax. in 1 frame (6 ch) at rated charge | |
Environmental conditions | Operating temperature | 0 °C to 40 °C |
Humidity range | 20 %rh to 85 %rh (no condensation) | |
Storage temperature | -10 °C to 60 °C | |
Humidity range | 0 %rh to 90 %rh (no condensation) | |
Operating environment | Indoors, overvoltage category II | |
Altitude | Up to 2000 m | |
Isolation voltage | Between I/O terminals and chassis | Maximum ±50 V |
Insulation resistance | Between primary and chassis | 500 Vdc, 30 MΩ or greater, 70 %rh humidity or less |
Between primary and I/O terminals *1 | 500 Vdc, 30 MΩ or greater, 70 %rh humidity or less | |
Between I/O terminals and chassis *1 | 50 Vdc, 30 MΩ or greater, 70 %rh humidity or less | |
Withstanding voltage | Between primary and chassis | No abnormalities at 1500 Vac for 1 minute. |
Between primary and I/O terminals *1 | No abnormalities at 1500 Vac for 1 minute. | |
Outline drawing | 430(16.93)(MAX 440(17.32))W×173(6.81)H× 620(24.41)MAX 695(27.36)D mm(inch) | |
Weight | Approx. 34 kg (75 lbs) | |
Accessories | Power cord × 1, Rear panel cover set × 1, Temperature measurement boxes × 6, Temperature measurement cables × 6,TRIP connector × 1, Signal I/O connector × 1, LAN cable × 1, Heavy object warning label × 1, Operation Manual(Japanese and English,one each) × 1, Safety Information × 1, China RoHs sheet × 1 *Cable set is not included. Please purchase the optional cable set together with the main unit. | |
Electromagnetic compatibility *2 *3 | Complies with the requirements of the following directive and standard. EMC Directive 2014/30/EU EN 61326-1 (Class A*4) EN 55011 (Class A*4、Group 1*5) EN 61000-3-2 EN 61000-3-3 Applicable under the following conditions: The maximum length of all cabling and wiring connected to this product is less than 5 m. | |
Safety | Complies with the requirements of the following directive and standard. Low Voltage Directive 2014/35/EU *3 EN 61010-1 (Class I *6 , Pollution Degree 2 *7) EN IEC 61010-2-030 |
*1 The input/output terminals refer to charging and discharging terminals connected to the DUT, voltage sensing terminal, and external signal input/output. *2 Does not apply to specially ordered or modified products. *3 Only for products with CE marking / UKCA marking on their body. *4 This is a Class A instrument. This product is intended for use in an industrial environment. This product may cause interference if used in residential areas. Such use must be avoided unless the user takes special measures to reduce electromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *5 This product belongs to Group 1 products. This product does not generate and/or use intentionally radio-frequency energy, in the form of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *6 This is a Class I instrument. Be sure to ground this product’s protective conductor terminal. The safety of this product is guaranteed only when the product is properly grounded. *7 Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength or surface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasional temporary conductivity caused by condensation.