Model | Single-phase output | Single-phase/three-phase switchable model | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
PCR1000WEA | PCR2000WEA | PCR3000WEA2 | PCR6000WEA2 | PCR12000WEA2 | PCR18000WEA2 | PCR24000WEA2 | PCR30000WEA2 | PCR36000WEA2 | ||
PCR6000WEA2R | PCR12000WEA2R | PCR18000WEA2R | PCR24000WEA2R | PCR30000WEA2R | PCR36000WEA2R | |||||
Maximum peak current *11 | 4 times the maximum output current | |||||||||
Inrush current capacity *3 | 3 times the rated current (0.07 s) *12 1.4 times the rated current (0.5 s) | 1.4 times the rated current (0.5 s) | ||||||||
Efficiency *10 | 82 %(TYP) | 85 %(TYP) |
0
PCR-WEA/WEA2_Output
Related specifications : PCR-WEA/WEA2 Series
- PCR-WEA/WEA2_Example of the combined system using different models
- PCR-WEA/WEA2_Example of the combined system using same models
- Communication Interface (Common Specification)
- PCR-WEA/WEA2_ Related to IEC61000 standard
- PCR-WEA/WEA2_ DC mode output rating regenerative
- PCR-WEA/WEA2_ DC mode output rating
- PCR-WEA/WEA2_ AC mode output rating regenerative
- PCR-WEA/WEA2_ AC mode output rating
- PCR-WEA/WEA2_ Input rating (AC rms) regenerative
- PCR-WEA/WEA2_ Input rating (AC rms)
- PCR-WEA/WEA2_Output_DC
- PCR-WEA/WEA2_Output_AC
- PCR-WEA/WEA2_Regeneration Function
- PCR-WEA/WEA2_Measurement
- PCR-WEA/WEA2_Output Voltage Stability (Phase Voltage)
- PCR-WEA/WEA2_Output Impedance Setting
- PCR-WEA/WEA2_Output Impedance-Reactance component(Response: SLOW)
- PCR-WEA/WEA2_Output Impedance-Reactance component(Response: MED)
- PCR-WEA/WEA2_Output Impedance-Reactance component(Response: FAST)
- PCR-WEA/WEA2_Output
- PCR-WEA/WEA2_Input (AC rms)
- PCR-WEA/WEA2_General
- PCR-WEA/WEA2_ Limit Values and Protection Functions (Common Specification)