Item/Model | PBZ20-20A | PBZ20-20 | PBZ40-10 | PBZ60-6.7 | PBZ80-5 | |
---|---|---|---|---|---|---|
Internal signal source’s DC signal control | Control voltage input | By applying approximately 0 V to approximately ±10.0 V, you can generate 0 % to ±100 % of the rated output. | ||||
Control voltage ratio input | By using a 10 kΩ external variable resistor to change the internal reference voltage’s voltage-divider ratio, you can generate 0 % to ±108 % of the rated output. | |||||
Output ON/OFF control input | External contact input to turn output on and off. | |||||
Shutdown input | External contact input to turn the POWER switch off. | |||||
Status output | CV/CC mode, output on, alarm occurrence |