| Item/Model | PAV10-40 | PAV20-20 | PAV36-12 | PAV60-7 | PAV100-4 | PAV160-2.6 | PAV320-1.3 | PAV650-0.64 |
|---|
| Maximum line regulation *5 (for the rated output voltage) | 0.01% +2mV | 0.01% |
|---|
| Maximum load regulation *6 (for the rated output voltage) |
|---|
| Ripple noise *7 | 20 MHz, p-p | 50mV | 50mV | 50mV | 50mV | 80mV | 100mV | 150mV | 250mV |
|---|
| 5 Hz to 1 MHz, rms | 5mV | 6mV | 6mV | 7mV | 8mV | 10mV | 25mV | 60mV |
|---|
| Temperature coefficient | 30 PPM /°C (after a 30 minute warm-up, for the rated output voltage) |
|---|
| Aging drift *8 (for the rated output voltage) | 0.02% |
|---|
| Initial drift *9 (for the rated output voltage) | 0.05% +2 mV | 0.05% |
|---|
| Maximum remote sensing compensation voltage (single line (positive or negative)) | 1V | 1V | 2V | 3V | 5V | 5V |
|---|
| Rise time *10 | 15ms | 30ms | 30ms | 50ms | 50ms | 80ms | 150ms | 150ms |
|---|
| Fall time | At full load *10 | 10ms | 10ms | 15ms | 30ms | 50ms | 100ms | 150ms | 150ms |
|---|
| Td (typ) *11 | 210ms | 250ms | 320ms | 380ms | 1200ms | — |
|---|
| No load a *12 | 40ms | 65ms | 85ms | 100ms | 250ms | — |
|---|
| No load b *13 | 200ms | 200ms | 290ms | 310ms | 1100ms | 2000ms | 2500ms | 3000ms |
|---|
| Transient response time *14 | 1 ms or less | 2 ms or less |
|---|
| Output hold time (typ) *15 | 15ms | 16ms | 16ms | 15ms |
|---|