PXZ_External digital output
Item | Common to all models |
---|
Output points | 6 points (Polarity switchable) |
---|
Output form | Semiconductor relay output |
---|
Selecting function | OFF | Do not use terminals |
---|
LOAD ON | Outputs a signal when load is turned on |
---|
POWER ON | Signal is output when power supply is on and load is possible |
---|
H ALARM OUT | Output a signal when a HIGH alarm occurs |
---|
L ALARM OUT | Output a signal when a LOW alarm occurs |
---|
CC STATUS | Output a signal when operating in the CC mode |
---|
CV STATUS | Output a signal when operating in the CV mode |
---|
SEQ TRIG OUT | Output the trigger for sequence |
---|
SEQ STATUS | Signal is output while the sequence is running |
---|
EXT DIN BUSY | Output a signal when the digital input is in BUSY status |
---|
MEM1 ACT TIME | Signal is output when the setting is completed for preset memory 1 |
---|
MEM2 ACT TIME | Signal is output when the setting is completed for preset memory 2 |
---|
RELAY DRIVE | Links with load on/off and outputs a signal with a time difference of approx. 100 ms. You can set this parameter to only Ch.6. |
---|