| AC voltage *1 | Rating | 160 V / 320 V *2 |
|---|
| Setting range | 0 V to 161.0 V, 0 V to 322.0 V |
|---|
| Resolution | 0.1 V |
|---|
| Setting accuracy (phase voltage) *3 *4 | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) |
|---|
| Setting accuracy (Line voltage) *3 *4 | ±(0.3 % of setting + 0.3 V), ±(0.3 % of setting + 0.6 V) *5 |
|---|
| Maximum current *1 *6 | Single-phase output | 10 A / 5 A | 20 A / 10 A | 30 A / 15 A | 60 A / 30 A | 120 A / 60 A | 180 A / 90 A | 240 A / 120 A | 300 A / 150 A | 360 A / 180 A |
|---|
| Single-phase three-wire output, Three-phase output | – | 10 A / 5 A | 20 A / 10 A | 40 A / 20 A | 60 A / 30 A | 80 A / 40 A | 100 A / 50 A | 120 A / 60 A |
|---|
| Phase | 1P | 1P2W, 1P3W, 3P4W switchable |
|---|
| Power capacity | Single-phase output | 1 kVA | 2 kVA | 3 kVA | 6 kVA | 12 kVA | 18 kVA | 24 kVA | 30 kVA | 36 kVA |
|---|
| Three-phase output | – | 3 kVA | 6 kVA | 12 kVA | 18 kVA | 24 kVA | 30 kVA | 36 kVA |
|---|
| Single-phase three-wire output | – | 2 kVA | 4 kVA | 8 kVA | 12 kVA | 16 kVA | 20 kVA | 24 kVA |
|---|
| Load power factor | 0 to 1 (leading or lagging) |
|---|
| Frequency | Setting range | 1 Hz to 5 kHz *7 (5 kHz -3dB, <40 Hz derating required) |
|---|
| Resolution | 0.01 Hz(1.00 Hz to 100.0 Hz), 0.1 Hz(100.0 Hz to 1000 Hz), 1 Hz(1000 Hz to 5000 Hz) |
|---|
| Accuracy *3 | ±0.01 %, Temperature coefficient : ±0.005 %/°C |
|---|
| Phase | Resolution | – | 0.01*13 , 0.1° (1 Hz to 500 Hz), 1° (500 Hz to 4 kHz), 2° (4 kHz or more) |
|---|
| Accuracy *3 | – | Within ±(0.4° + fo×0.9°) *8 fo: frequency [kHz] [kHz] |
|---|