PAV_External control

Output voltage control using external voltage0% to 100% of the rated output voltage (application voltage range selectable: 0 V to 5 V or 0 V to 10 V) Accuracy and linearity: ± 0.5% of the rated output voltage
Output current control using external voltage *10% to 100% of the rated output current (application voltage range selectable: 0 V to 5 V or 0 V to 10 V) Accuracy and linearity: ± 1% of the rated output current
Output voltage control using external resistance0% to 100% of the rated output voltage (application resistance range selectable: 0 Ω to 5 kΩ or 0 Ω to 10 kΩ) Accuracy and linearity: ± 1% of the rated output voltage
Output current control using external resistance *10% to 100% of the rated output current (application resistance range selectable: 0 Ω to 5 kΩ or 0 Ω to 10 kΩ) Accuracy and linearity: ± 1.5% of the rated output current
Output shutoff (SO) controlExternal voltage application: 0 V to 0.6 V, 4 V to 15 V, or a contact switch. Positive or negative logic selectable.
Output current monitor *1Monitor voltage range selectable: 0 V to 5 V or 0 V to 10 V, Accuracy: 1%
Output voltage monitorMonitor voltage range selectable: 0 V to 5 V or 0 V to 10 V, Accuracy: 1%
Normal operation status signalNormal (4 V to 5 V), abnormal (0 V), output resistance 500 Ω
Parallel operation *2 *3Possible up to six power supplies. Master-slave operation with a current balance function.
Series operation *4Possible up to two power supplies.
Constant voltage/constant current mode (CV/CC) signalOpen collector output (maximum application voltage 30 V, maximum sink current 10 mA)
Low level (on) during constant current (CC) mode High level (off) during constant voltage (CV) mode
Output on / off control (ILC)Output can be shut off using a contact switch or the like (maximum voltage between terminals: 5 V). When open: Output off When shorted: Output on
Local / remoteCan be switched by applying an external voltage or by opening or shorting the circuit.
Local: 2 V to 15 V or open Remote: 0 V to 0.6 V or shorted
External control status signalOpen collector output (maximum application voltage 30 V, maximum sink current 10 mA)
High level (off) during local mode Low level (on) during external control
Trigger output signalMaximum low level output signal: 0.8 V
Minimum high level output signal: 3.8 V, maximum high level output signal: 5 V
Maximum source current: 16 mA, output trigger signal span: 20 μs (typ)
Trigger input signalMaximum low level input signal: 1.2V
Minimum high level input signal: 3.5 V, maximum high level input signal: 5 V
Maximum sink current: 16 mA, positive edge trigger span: 10 μs (min)
Tr/Tf: 1 μs (max)
Program signal output 1Open collector output (maximum application voltage 25 V, maximum sink current 100 mA)
Program signal output 2

*1. In output current control, the current, linearity, and monitor accuracies do not include the load variation caused by initial drift and temperature drift of internal components. *2. For parallel operation of two or more PAV series power supplies with the same rating, the minimum load current is 5% of the rating or higher. For parallel operation of four or less models with rated output voltage of 160 V to 650 V, the minimum load current is 5% of the rating or higher. For parallel operation of more than four, the minimum load current is 20% of the rating or higher. *3. The ammeter’s display accuracy when the total current is displayed on the master unit is 2% ± 1 count of the total of rated currents. *4. An external protection diode is necessary.