For a single-phase three-wire output, you will need two PCR-LE units and the optional 2P05-PCR-LE (single-phase three-wire output driver).
For a three-phase output, you will need three PCR-LE units and the optional 3P05-PCR-LE (three-phase output driver).
A DC output is also available, but please note that the rated DC voltage is limited to 70 % of the value in the AC mode.