SD009-PCR-LE/WE (Quick Immunity Sequencer 2) – Update

Update Module for Quick Immunity Sequencer 2

This is the latest update module for Quick Immunity Sequencer 2. To install this module, your PC must already install Quick Immunity Sequencer 2.

Ver.

4.1.8

Last update

2026/6/08

Configuration

  • Windows10 (x86/x64)
  • Windows11

Notes

*Attention when upgrading to SD009-PCR-LE_Ver3.3.7 or later.

Download

Release Notes

Ver4.1.8
2026-06-08

Quick Immunity Sequencer 2

  • Improvement Added “When the Output Turns OFF” to the Display Options in the Option menu.
  • Improvement Added the following items to “Affect soon the Output” in the Display Options of the Option menu:
    ・If changing the standard test in the standard-selection pane requires you to change the PCR-LE/WE output while the output is ON.
    ・If loading a test condition file requires you to change the PCR-LE/WE output while the output is ON.
Ver4.1.7
2025-03-06

Quick Immunity Sequencer 2

  • Resolved issues Fixed the issue where H range value could not be set during simulation mode.
Ver4.1.6
2024-10-21

Quick Immunity Sequencer 2

  • Resolved issues Fixed issue where sometimes response setting is not reflected when starting the application.
Ver4.1.5
2024-05-17

Quick Immunity Sequencer 2

  • Improvement IEC61000-4-11、IEC61000-4-34 When the line voltage is selected, the phase angle between the lines is displayed below the starting phase angle, but it is now displayed not only for "Ua-Ub" but also for "Ub-Uc" and "Uc-Ua".
Ver4.1.4
2024-01-26

Quick Immunity Sequencer 2

  • Resolved issues There was a problem on which the waveform progress bar of the waveform progress returns to the initial start position at the end of each sequence when operating the waveform progress bar with a dip simulator connected.
Ver4.1.3
2023-10-12

Quick Immunity Sequencer 2

  • Improvement In each test under the IEC61000-4-13 standard, the amplitude accuracy of high-order harmonics deteriorates. Therefore, correction is applied by means of a correction function to improve the issue (only for PCR-WEA and PCR-WE series). The correction is only compatible with "Fast response (FAST) mode" of PCR response (voltage response characteristics).
Ver4.1.2
2023-06-29

Quick Immunity Sequencer 2

  • Resolved issues In the three-phase output voltage variation test in the IEC61000-4-11 and IEC61000-4-34 standards, there was a problem that the voltage did not drop when the fall time was set to 0.000s.
Ver4.1.1
2023-1-31

Quick Immunity Sequencer 2

  • Improvement This version operates in Windows 11.
  • Resolved issues 61000-4-13 Interharmonics 15.0~20.0 Δf Corrected from 0.5 to 0.2.
  • New Feature 61000-4-17 Added 2×,3×,and 6× frequency settings for ripple test.
Ver4.1.0
2021-4-8

Quick Immunity Sequencer 2 / Wave Bank Memory

  • New Feature This version operates also in AC power supply PCR-WEA series.
  • Resolved issues When the Setting Limits of Instruments menu was opened, there was a problem of which an error occurs in Setting Limits dialog.
  • Improvement If AC power supply detect the command error of over-range etc. during sending program data for test start, test will be stopped.
  • Improvement Even if it is in simulation mode, reading and drawing are able to perform from waveform data file.
Ver 4.0.4
2020-12-24

Quick Immunity Sequencer 2

  • Improvement Operation manual was updated.
Ver 4.0.3
2019-12-25

Quick Immunity Sequencer 2 / Wave Bank Memory

  • Resolved issues There was a problem which did not match progress with an actual progress bar only at the time of DSI use.
  • Resolved issues There was a problem on which the function to return sensing mode and a response at the time of PCR-WE use has not been operated.
  • Resolved issues There was a change which lowers the minimum of voltage to 5V from 50V.
  • Resolved issues When the error of cable connection, FUSE, and OHP occurred in DSI, there was a change which stop the test and turn off the output of PCR-LE/WE.
  • Resolved issues There was a problem on which the waveform of Ua-Ub differed from the preview waveform by 3 phase dip.
  • Resolved issues Correction has been made that only numerical characters could be input.
Ver 4.0.2
2019-9-18

Quick Immunity Sequencer 2

  • Resolved issues There was a problem out of which an error occurs at the time of first time starting of this application.
Ver 4.0.1
2019-6-27

Quick Immunity Sequencer 2

  • Improvement This version comply with "IEC61000-4-13 Meister curve 2015".
Ver 4.0.0
2019-6-3

Quick Immunity Sequencer 2

  • New Feature This version operates also in PCR-WE series.
Ver 3.3.7
2018-2-20

Quick Immunity Sequencer 2

  • Resolved issues The decimal point (comma) of Europe is adapted.
Ver 3.3.6
2016-3-28

Quick Immunity Sequencer 2

  • New Feature The response options was added to the options menu. Setup for response of PCR-LE in IEC61000-4-29 and other standards were added. Moreover, added a function that sensing mode and response were returned to last setting when application exit.
Ver 3.3.5
2016-3-3

Quick Immunity Sequencer 2

  • Resolved issues IEC61000-4-29 There was a problem which does not become High Impedance by the DC Short interruptions. As this solution serge suppression function turned OFF. Firmware Ver4.50 of PCR-LE becomes effective to this function.
Ver 3.3.4
2015-8-28

Quick Immunity Sequencer 2 Wave Bank Memory

  • Improvement This version operates in Windows 10.
Ver 3.3.3
2015-4-8

Quick Immunity Sequencer 2

  • Improvement IEC61000-4-17 The setting lower limit of DC voltage (Udc) was changed into 10.0V from 50.0V.
Ver 3.3.2
2014-10-20

Quick Immunity Sequencer 2

  • Resolved issues There was a problem in which communication error was occurred, when DSI series was connected by RS232C.
Ver 3.3.1
2014-5-23

Quick Immunity Sequencer 2

  • Resolved issues IEC61000-4-13 There was a problem in which command error occurred during a test of the meister curve. (Only LAN hislip)
Ver 3.3.0
2014-4-7

Quick Immunity Sequencer 2

  • New Feature This version operates also in DSI series.
Ver 3.2.0
2013-3-22

Quick Immunity Sequencer 2

  • New Feature The sending progress bar was added.
  • New Feature The visual progress of test was added.
  • New Feature The following item was added to the option menu. Show confirmation Message of change setting - Change Setting that affect soon the output value - Change Seq Tab value Display test progress bar Test result file is not saved
Ver 3.1.1
2013-2-18

Quick Immunity Sequencer 2

  • Resolved issues IEC61000-4-11, IEC61000-4-34 There was a problem in which a command error occurred at Phase voltage on the Voltage dips.
Ver 3.1.0
2013-2-1

Quick Immunity Sequencer 2

  • Resolved issues IEC61000-4-11, IEC61000-4-34 There was a problem in which the angle of Ua phase did not shift at Line voltage in three-phase.
  • Resolved issues IEC61000-4-11, IEC61000-4-34 There was a problem in which the angle of each phase did not ramp in the part of the fall and rise of the Voltage variation at Line voltage in three-phase.
Ver 3.0.2
2012-12-20

Quick Immunity Sequencer 2

  • Improvement IEC61000-4-27 Setup of the reference phase is added and enabled the reference phase to change.
  • Improvement IEC61000-4-11, IEC61000-4-34 In single-phase 3-wire or if Phase select is set to Line voltage in three-phase, the phase voltage that you enter is converted to the nearest line voltage and displayed under the phase voltage.
  • Improvement IEC61000-4-11, IEC61000-4-34 The cycle value of Dips and Short that you enter is converted to the nearest sec value and displayed under the cycle value.
Ver 3.0.1
2012-11-27

Quick Immunity Sequencer 2

  • Improvement IEC61000-4-11, IEC61000-4-34 When the Line voltage is selected, the waveform preview can be drawn on the line voltage.
  • Improvement IEC61000-4-14 When the first Seq is selected at Interval, the phase angle of start is 0 degree.
  • Improvement IEC61000-4-28 The phase angle of start in the first Seq is 0 degree.
  • Resolved issues There was a problem in which Setting Limits did not correspond to the parallel system.
Ver 3.0.0
2012-10-23

Quick Immunity Sequencer 2

  • New Feature This version operates also in single phase - three wire system.
  • Improvement Improved to make zooms in a waveform preview one more step.
  • Improvement Improved to make a waveform preview similar to an output waveform.
  • Resolved issues There was a problem which had disorder in the waveform preview depend on a setting value.
  • Resolved issues There was a problem which the waveform preview did not correspond to the voltage between lines.
Ver 2.0.1
2012-10-9

Quick Immunity Sequencer 2

  • Resolved issues In the case of IEC61000-4-34, there was a problem that the error message "Setting voltage is out of range" was displayed even if setting voltage was within the limits.
  • Resolved issues There was a problem in which IEC61000-4-11 Short interruption did not operate when IT01-PCR-L was used.
Ver 2.0.0
2012-6-20

Quick Immunity Sequencer 2 / Wave Bank Memory

  • New Feature This version operates also in three phase system.
  • New Feature This version operates also in three phase system.
Ver 1.0.1
2012-2-17

Quick Immunity Sequencer 2 / Wave Bank Memory

  • Improvement English contents and user's manual can be now referenced from the Help menu.
  • Improvement English contents can be now referenced from the Help menu.
Ver 1.0.0
2011-12-26

Quick Immunity Sequencer 2 / Wave Bank Memory

  • New Feature The first release.