SD007-PFX (BPChecker3000 V1/V2) V2

Published: December 2020 Please check the publication date of this article. The information on products, pricing, and technology may not reflect the latest updates.

VER 2.0.9.01
2026-7-29

PFX firmware / BPC3000

Improvement
Added support for additional model IDs.
New Feature
Added LAN communication capability to the temperature chamber interface.
VER 2.0.8.02
2025-3-04

PFX firmware / BPC3000

Resolved issues
Fixed the issue where a test does not complete at the set minimum voltage when the test is performed using an I-V characteristics profile created with the Test Condition Editor.
Resolved issues
Fixed the issue where an "element is out of effective range" error occurs when a BPCL3 file is loaded with the Graph Viewer.
Improvement
This version operates in Windows 11.
VER 2.0.7.00
2023-2-14

PFX firmware

Resolved issues
Fixed a problem that may not work with CV charging when charging CC-CV using a battery with high impedance.
Resolved issues
Fixed a problem that only the maximum cell voltage is not displayed in the test result when OP02-PFX is installed.
Resolved issues
Fixed a problem that an incorrect mode is displayed (recorded) when operating in cell CV mode.
VER 2.0.6.02
2021-1-20

PFX firmware / BPC3000

Resolved issues
Fixed a problem that activated the overvoltage protection (OVP) upon completion of the charge in combination with PWR-01 series.
Resolved issues
Fixed a problem when the test was paused and resumed in the last profile, only one profile was excecuted to complete the test regardless of the resuming position.
Resolved issues
Fixed a problem that decreased the detection accuracy of the overcharge capacity protection (OAH) (the OAH detection value (capacity: Ah) was rounded down to the nearest integer).
Improvement
Fixed a problem that required the time to switch profiles under the test condition with many profiles depending on the PC environment.
VER 2.0.5.00
2020-9-03

PFX firmware

Resolved issues
Fixed a problem that caused an error due to false detection of the option board when the option board was not inserted.
VER 2.0.4.00
2018-6-01

BPC3000

New Feature
Added support for model Ids that combine power supplies (PWR-01) and electronic loads (PLZ-5W).
New Feature
Added the “Save the data for Graph Viewer” option to TestExecutive. When the check box is cleared, memory consumption is suppressed, which makes long-term profile operation possible.
Improvement
Improved the memory usage algorithm and processing speed when a profile is run over a long time period on TestExecutive.
Resolved issues
Fixed a problem that was not applying selections correctly when a profile with the Delta Time of Data Record Method set to Fix Time is edited on Test Condition Editor.
VER 2.0.3.00
2017-12-01

PFX firmware / BPC3000

Resolved issues
Fixed a problem that was displaying an incorrect error code for electronic load alarms.
Resolved issues
Fixed a problem that the profile template created before V 2.01 is not displayed.
Resolved issues
Fixed a problem that was resetting the unbalanced margin display on the profile screen.
VER 2.0.2.12
2017-1-23

PFX firmware / BPC3000

Resolved issues
Fixed a problem that was always causing the test to stop with an OTP when I-V characteristic Prof was executed immediately after starting the PFX. (This problem could be reproduced only when a thermometer was not connected to the PFX.)
New Feature
Added support for the ID7306 model.
Improvement
Improved the PFX search algorithm on TestExecutive and IoConfig.
Resolved issues
Refined the model ID file loading process.
Resolved issues
Fixed a problem that was always causing the cell CV to operate during CC-CV charge Prof or pattern Prof and preventing current from flowing when all cell voltage measurements were turned off when an OP board was installed.
Resolved issues
Fixed a problem that causing an exception when no channels could be connected during TestExecutive startup.
VER 2.0.1.03
2016-7-29

PFX firmware / BPC3000

Resolved issues
Fixed a problem that was causing the cell CV function to operate when a given condition was met even when there was no OP board.
Resolved issues
Fixed a problem that was preventing programs from proceeding to the next loop if “RestTemp (LastStep)” is enabled in a pattern profile or I-V characteristic profile when there was no thermometer connected (e.g., OPEN).
Improvement
Redesigned the new text output format. (The two-row column header was changed to one.)
Improvement
Redesigned the GraphViewer text export function so that the elapsed time column is changed to the total time column.
New Feature
Added a preset timeout function for temperature chamber synchronization.
Improvement
Changed the supported KI-VISA version to v5.5.0. (To use temperature chambers, update the KI-VISA version to v5.5.0 or later.)
VER 2.0.0.38
2016-1-06

Global / BPC3000

New Feature
Added a cell CV function.
New Feature
Voltage measurement of up to 72 cells is possible by connecting SL01-PFXs.
Improvement
Drastically improved the operability of Graph Viewer. [Description] • Added an auto creation wizard for I-V characteristic graphs. • Printing can be executed from the shortcut menu. • Improved the operability of moving and zooming data lines. • Redesigned the pane configuration. • Redesigned the shortcut menu. • Redesigned button arrangement.
Improvement
Drastically improved the print content of Graph Viewer. [Description] • Improved the smudging of graphs during printing. • Redesigned grayscale printing. • Redesigned the print format of test condition and the like.