PIA4850
PIA4850
25,000円 (税込:27,500円)
- USB 2.0 compatible
- Can be used with Windows Vista/XP/2000.
- Operates using bus power. Requires no AC adapter.
- Allows read-back of output values and status monitoring.
- Can control up to 32*1 DC power supplies that equip TP-BUS*2. (Different power supply models can be combined.) TP-BUS connection can be extended up to 200 m.
*1 The maximum controlable units are 31 when the connections include PAM series or PMR series unit. *2 TP-BUS (Twist-Pair BUS) is an original Kikusui interface.
Out of stock
カート機能が動くまでの
Specifications
Specifications
Open in a new windowZOOM
| Item | Description | |
|---|---|---|
| TP-BUS | Connections | The connections given below are possible using the provided TP-BUS connector Expansion unit PIA4820 : 4 units can be connected (Total length: 200 m or less, number of twists: 1 twist/cm or more) |
| Number of controlled units*1 | PAS Series : Maximum 32 units | |
| PWR Series : Maximum 32 units | ||
| PAM Series : Maximum 31 units | ||
| PMR Series : Maximum 31 units | ||
| Polarity | Not supported | |
| Conforming power wiring | Stranded wire: 0.32mm2 (AWG22) Total length: 200m or less 0.20mm2 (AWG24) total length: 20m or less | |
| USB | Conforms to USB2.0 specification. Conforms to USBTMC-USB488 device class specification Communication speed 12Mbps (Full speed) High power device (Current consumption: 200mA) | |
| OS(Windows) | 2k (x86, SP4 + Update Rollup 1) XP (x86, SP2 or later) Vista (x86/x64) 7 (x86/x64) 8 (x86/x64) | |
| VISA specification | Ver. 3.0 or higher | |
| Operating ambient temperature / Humidity range | 0 °C to 40 °C, 10 % rh – 90 % rh (No condensation.) | |
| Storage ambient temperature / Humidity range | -20 °C to 70 °C, 10 % rh – 90 % rh (No condensation.) | |
| Installation location | Indoors, maximum height 2000 m | |
| Safety | Conforms to Low-Voltage Directive 2014/35/EU, EN61010-1 Protection Class I, Pollution Degree 2. | |
| Dimensions (mm (inch)) (maximum dimensions) / Weight | 95W x 58D x 18H mm / Approx. 100 g | |
| Accessories | USB cable (1m) TP-BUS connector, TP-BUS cable (1m) Magnet sheet for bottom fixing CD (instruction manual, driver files, sample programs, etc.) | |
*1: The maximum controlable units are 31 when the connections include PMR series unit.
Description of Control
Open in a new windowZOOM
| Applied Series | PAS | PWR | PAM | PMR |
|---|---|---|---|---|
| Output voltage setting | ✓ | ✓ | ✓ | ✓ |
| Output current setting | ✓ | ✓ | ✓ | ✓ |
| Queries the output voltage value | ✓ | ✓ | not controllable | not controllable |
| Queries the output current value | ✓ | ✓ | not controllable | not controllable |
| Output voltage readback | ✓ | ✓ | ✓ | ✓ |
| Output current readback | ✓ | ✓ | ✓ | ✓ |
| Designation / Queries of OUTPUT channel number | not controllable | not controllable | not controllable | ✓ |
| Designation of output channel number to be displayed | not controllable | not controllable | not controllable | ✓ |
| Overvoltage protection startup monitoring setting | ✓ | ✓ | not controllable | not controllable |
| Queries the overvoltage protection startup monitoring | ✓ | ✓ | not controllable | not controllable |
| Overcurrent protection startup monitoring setting | ✓ | ✓ | not controllable | not controllable |
| Queries the overcurrent protection startup monitoring | ✓ | ✓ | not controllable | not controllable |
| Output ON / OFF | ✓ | ✓ | ✓ | ✓ |
| Power switch OFF | ✓ | ✓ | not controllable | not controllable |
| Panel Lock ON / OFF | ✓ | ✓ | ✓ | ✓ |
*For other models (analogue control models), see the PIA4800 series catalogue or contact us separately.
For required drivers and components
Open in a new windowZOOM
| Wavy application software | VB、VBA、VC++、LabVIEW | ||
|---|---|---|---|
| VISA (including USB-TMC driver) | Required | Required | |
| PIA4800 instrument driver | IVI-COM/C | Not required | Required in some cases |
| IVI Shared Components | |||
* The latest drivers available at the Kikusui website.
Manual
PIA4850
Updater/Driver