Dip Simulator
DSI Series
DSI-Series
価格お問い合わせ
- DSI1020: Compatible with single-phase 2-wire
- DSI3020: Supports single-phase 2-wire, single-phase 3-wire, 3-phase 3-wire, and 3-phase 4-wire
- Fast voltage switching (rise time 1μs~5μs)
- Supports voltage dips (0%, 40%, 70%, 80%)
- Supports phase voltage/line voltage dip test*.
- Supports a maximum line input voltage of 500 V (DSI3020)
Only DSI3020 supports line-to-line voltage dip test.
- Features
Features
For the Voltage dips, short interruptions and voltage variations immunity test system
complying with IEC61000-4-11 (2004)
The DSI Series is an option unit used to configure the test system complying with “Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests” as defined in the IEC61000-4-11 (2004) standard. It can be used in combination with the Kikusui AC power supplies (PCR-LE/LE2 series). It meets the test requirement of: high- speed voltage switching (rise time: 1 μs to 5μs), voltage dips (0 %, 40 %, 70 %, and 80 %), and phase-voltage and line-voltage tests.
*Quick Immunity Sequencer (model: SD009-PCR-LE/WE) is required.*Connecting cable with PCR-LE/LE2 series must be prepared by the customer.
The DSI3020 supports the voltage dip testing of 230V and 400V linevoltage systems required for the three-phase three-wire, and the three-phase four-wire.
[table id=”122″ /]Voltage dips, short interruptions and voltage variations immunity test system

* Figure is for reference only. It may differ from an actual product. *Multiple AC power supplies are required for single-phase 3-wire, 3-phase 3-wire, and 3-phase 4-wire outputs.
- With USB: Contact Us
- With GPIB: Contact Us
Line-up
表示可能なバリエーションがありません。 考えられる原因: ※「在庫切れバリエーションを非表示」オプションが有効になっています。 |
Overview
For the Voltage dips, short interruptions and voltage variations immunity test system
complying with IEC61000-4-11 (2004)
The DSI series is an optional unit for configuring a “Voltage Dip/Instantaneous Power Failure and Voltage Fluctuation Immunity Test System” in accordance with the IEC61000-4-11 Ed3.0 (2020) standard. It can be used in combination with our AC power supply PCR-LE/LE2 series. The unit supports high-speed voltage switching (rise time 1μs to 5μs), voltage dips (0 %、40%, 70 %、80% ), and phase voltage/line voltage dip tests required by the test.
*Quick Immunity Sequencer (model: SD009-PCR-LE/WE) is required.*Connecting cable with PCR-LE/LE2 series must be prepared by the customer.
The DSI3020 supports the voltage dip testing of 230V and 400V linevoltage systems required for the three-phase three-wire, and the three-phase four-wire.
Model | Maximum current (per phase) | Wiring configuration | DIP level | Compliant standards | Remarks | |
---|---|---|---|---|---|---|
Single phase | Three-phase | |||||
DSI1020 * | 16A | ✓ | – | 0/40/70/80% | IEC61000-4-11 Ed3.0(2020) | For Single Phase only |
DSI3020 * | 16A | ✓ | ✓ | 0/40/70/80% | IEC61000-4-11 Ed3.0(2020) | For Single Phase or Three Phase |
* Excluding the PCR500LE, PCR1000LE and PCR1000WEA, since those model do not have enough output capacity.
Voltage Dip/Instantaneous Power Loss and Voltage Fluctuation Immunity Test Systems
*The diagram is an image. Actual product may differ. *Multiple AC power supplies are required for single-phase 3-wire, 3-phase 3-wire, and 3-phase 4-wire outputs.