Dip Simulator

DSI Series

DSI-Series

価格お問い合わせ

  • DSI1020: Compatible with single-phase 2-wire
  • DSI3020: Supports single-phase 2-wire, single-phase 3-wire, 3-phase 3-wire, and 3-phase 4-wire
  • Fast voltage switching (rise time 1μs~5μs)
  • Supports voltage dips (0%, 40%, 70%, 80%)
  • Supports phase voltage/line voltage dip test*.
  • Supports a maximum line input voltage of 500 V (DSI3020)

Only DSI3020 supports line-to-line voltage dip test.


表示可能なバリエーションがありません。

考えられる原因:
• 価格が設定されていない
• 在庫切れ
• バリエーションが非公開

※「在庫切れバリエーションを非表示」オプションが有効になっています。
SKU: DSI-Series
  • Features

Features

For the Voltage dips, short interruptions and voltage variations immunity test system
complying with IEC61000-4-11 (2004)

The DSI Series is an option unit used to configure the test system complying with “Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests” as defined in the IEC61000-4-11 (2004) standard. It can be used in combination with the Kikusui AC power supplies (PCR-LE/LE2 series). It meets the test requirement of: high- speed voltage switching (rise time: 1 μs to 5μs), voltage dips (0 %, 40 %, 70 %, and 80 %), and phase-voltage and line-voltage tests.

*Quick Immunity Sequencer (model: SD009-PCR-LE/WE) is required.*Connecting cable with PCR-LE/LE2 series must be prepared by the customer.

The DSI3020 supports the voltage dip testing of 230V and 400V linevoltage systems required for the three-phase three-wire, and the three-phase four-wire.

[table id=”122″ /]

Voltage dips, short interruptions and voltage variations immunity test system

Voltage dips, short interruptions and voltage variations immunity test system

* Figure is for reference only. It may differ from an actual product. *Multiple AC power supplies are required for single-phase 3-wire, 3-phase 3-wire, and 3-phase 4-wire outputs.

  • With USB: Contact Us
  • With GPIB: Contact Us
The price of the main unit + the above price will be the customized amount.

Line-up

表示可能なバリエーションがありません。

考えられる原因:
• 価格が設定されていない
• 在庫切れ
• バリエーションが非公開

※「在庫切れバリエーションを非表示」オプションが有効になっています。

Overview

For the Voltage dips, short interruptions and voltage variations immunity test system
complying with IEC61000-4-11 (2004)

The DSI series is an optional unit for configuring a “Voltage Dip/Instantaneous Power Failure and Voltage Fluctuation Immunity Test System” in accordance with the IEC61000-4-11 Ed3.0 (2020) standard. It can be used in combination with our AC power supply PCR-LE/LE2 series. The unit supports high-speed voltage switching (rise time 1μs to 5μs), voltage dips (0 %、40%, 70 %、80% ), and phase voltage/line voltage dip tests required by the test.

*Quick Immunity Sequencer (model: SD009-PCR-LE/WE) is required.*Connecting cable with PCR-LE/LE2 series must be prepared by the customer.

The DSI3020 supports the voltage dip testing of 230V and 400V linevoltage systems required for the three-phase three-wire, and the three-phase four-wire.

Open in a new windowZOOM

ModelMaximum current (per phase)Wiring configurationDIP levelCompliant standardsRemarks
Single phaseThree-phase
DSI1020 *16A0/40/70/80%IEC61000-4-11 Ed3.0(2020)For Single Phase only
DSI3020 *16A0/40/70/80%IEC61000-4-11 Ed3.0(2020)For Single Phase or Three Phase

* Excluding the PCR500LE, PCR1000LE and PCR1000WEA, since those model do not have enough output capacity.

Voltage Dip/Instantaneous Power Loss and Voltage Fluctuation Immunity Test Systems

Voltage Dip/Instantaneous Power Loss and Voltage Fluctuation Immunity Test Systems

*The diagram is an image. Actual product may differ. *Multiple AC power supplies are required for single-phase 3-wire, 3-phase 3-wire, and 3-phase 4-wire outputs.