TOS9300_Leakage Current Test-Judgment function
Item | TOS9303LC |
---|
Behavior based on judgment | | Judgment starts after the judgment delay (Judge Delay). Buzzer volume level can be set in the range of 0 (OFF) to 10 for pass and fail separately. In an auto test, the buzzer is valid only for the judgment that takes place at the end of the program. |
---|
UPPER FAIL | Judgment method | UPPER FAIL results when a current greater than or equal to the upper limit (Upper) is detected. |
---|
Display | “U-FAIL” is displayed. |
---|
Buzzer | On |
---|
SIGNAL I/O | The Upper-FAIL signal is generated continuously until a STOP signal is received. |
---|
Lower FAIL | Judgment method | LOWER FAIL results when a current less than or equal to the lower limit (Lower) is detected. |
---|
Display | “L-FAIL” is displayed. |
---|
Buzzer | On |
---|
SIGNAL I/O | The Lower-FAIL signal is generated continuously until a STOP signal is received. |
---|
PASS | Judgment method | PASS judgment is made if U-FAIL or L-FAIL has not occurred when the test time elapses. |
---|
Display | “PASS” is displayed. |
---|
Buzzer | On (fixed to 50 ms) |
---|
SIGNAL I/O | The PASS signal is generated for the length of time specified by the Pass Hold setting. If Pass Hold is set to Infinity, the PASS signal is generated continuously until a STOP signal is received. |
---|
Upper Setting range | RANGE1 | DC, RMS: 0.1 μA(min.) to 200 μA(max), Peak: 0.1 μA(min.) to 282 μA(max) |
---|
RANGE2 | DC, RMS: 15.1 μA(min.) to 2.00 mA(max), Peak: 21.3 μA(min.) to 2.83 mA(max) |
---|
RANGE3 | DC, RMS: 151 μA(min.) to 20.00 mA(max), Peak: 213 μA(min.) to 28.3 mA(max) |
---|
RANGE4 | DC, RMS: 1.51 mA(min.) to 100 mA(max), Peak: 2.13 mA(min.) to 100 mA(max) |
---|
Lower Setting range | A value that is -1 digit from the upper setting range. |
---|
Judgment accuracy | Conforms to total accuracy(Read “reading” as “upper setting” of total accuracy.) |
---|