PXB_External digital output
| Item | Common to all models |
|---|
| Output points | 6 points (Polarity switchable) |
|---|
| Output form | Semiconductor relay output |
|---|
| Selecting function | OFF | Do not use terminals |
|---|
| OUTPUT ON | Outputting the signal while the output is ON |
|---|
| POWER ON | Signal is output when power supply is on and output is possible |
|---|
| H ALARM OUT | Output a signal when a HIGH alarm occurs |
|---|
| L ALARM OUT | Output a signal when a LOW alarm occurs |
|---|
| CC STATUS | Output a signal when operating in the CC mode |
|---|
| CV STATUS | Output a signal when operating in the CV mode |
|---|
| SEQ TRIG OUT | Output the trigger for sequence |
|---|
| SEQ STATUS | Signal is output while the sequence is running |
|---|
| EXT DIN BUSY | Output a signal when the digital input is in BUSY status |
|---|
| MEM1 ACT TIME | Signal is output when the setting is completed for preset memory 1 |
|---|
| MEM2 ACT TIME | Signal is output when the setting is completed for preset memory 2 |
|---|
| RELAY DRIVE | Output a signal after approx. 100 ms in step with on/off of the DC OUTPUT terminal output. You can set this parameter to only Ch.6. |
|---|