| Item | PMX32-3DU | PMX32-3TR | ||
|---|---|---|---|---|
| Output-on/ off delay | Applicable channels | All channels | ||
| Setup | Set the output on/off delay time. | |||
| Selectable range | 0.0 s to 99.9 s | |||
| Setting resolution | 0.1 s | |||
| Setting accuracy*1 | ±50 ms | |||
| Memory | Saves three combinations of voltage, current, OVP, OCP, and output-on delay/ off delay settings. | |||
| key lock | Select from the following three modes. • Loc1: Lock all keys except the OUTPUT and memory A, B, and C keys. • Loc2: Lock all keys except the OUTPUT key. • Loc3: Lock all keys and the rotary knob. | |||
| Tracking | Applicable channels | All channels | ||
| Operation mode | Tracking function 1 *2 | Absolute value change | ||
| Tracking function 2 *3 | Percentage change | |||
| Setting accuracy | CV setting accuracy | 0.4 % of rating + 40 mV | ||
| CC setting accuracy | 0.7 % of rating + 10 mA | |||
*1 The difference between the time from when the reference output reaches 5% of the setting to when the target output reaches 5% of the setting and the delay time setting. *2 In tracking function 1, the output can be varied within the output range of the reference channel voltage or current. *3 In tracking function 2, the output can be varied at the same percentage as the reference output in reference to the output at the start of the tracking function.