| PIN No | Signal name | Description |
|---|---|---|
| 1 | VMON | Output voltage monitor; outputs 0 V to 10 V for 0 % to 100 % of the rated output voltage. |
| 2 | IMON | Output current monitor; outputs 0 V to 10 V for 0 % to 100 % of the rated output current. |
| 3 | ACOM | External signal common for pins 1, 2, 4, and 14. *1 |
| 4 | EXT-V CV CONT | Output voltage control using external voltage; receives 0 V to 10 V to output 0 % to 100 % of the rated voltage. |
| 5 | ACOM | External signal common for pins 1, 2, 4, and 14. *1 |
| 6 | EXT-R CV CONT | Output voltage control using external resistance; uses 0 Ω to 10 kΩ to output 0 % to 100 % of the rated voltage. |
| 7 | EXT-R CV CONT COM | Common for output voltage control using external resistance. |
| 8 | N.C. | Not connected. |
| 9 | N.C. | Not connected. |
| 10 | N.C. | Not connected. |
| 11 | CV STATUS | On when the PMX series is in CV mode (open-collector output from a photocoupler).*2 |
| 12 | CC STATUS | On when the PMX series is in CC mode (open-collector output from a photocoupler).*2 |
| 13 | ALM STATUS | On when a protection function (OVP, OCP, or OHP) is activated (open-collector output from a photocoupler).*2 |
| 14 | EXT-V CC CONT | Output current control using external voltage; receives 0 V to 10 V to output 0 % to 100 % of the rated current. |
| 15 | ACOM | External signal common for pins 1, 2, 4, and 14. *1 |
| 16 | EXT-R CC CONT | Output current control using external resistance; uses 0 Ω to 10 kΩto output 0 % to 100 % of therated current. |
| 17 | EXT-R CC CONT COM | Common for output current control using external resistance. |
| 18 | OUT ON/OFF CONT | Output on/off control using external contact input. |
| 19 | DCOM | External signal common for pin 18.*1 |
| 20 | N.C. | Not connected. |
| 21 | N.C. | Not connected. |
| 22 | N.C. | Not connected. |
| 23 | OUT ON STATUS | On when output is on (output through an open-collector photocoupler).*2 |
| 24 | PWR ON STATUS | On when the power is on (output through an open-collector photocoupler).*2 |
| 25 | STATUS COM | Status signal common for pins 11, 12, 13, 23, and 24. |
*1. During remote sensing, this is the negative electrode (-S) of sensing input. When remote sensing is not being performed, this isconnected to the negative output. *2. Open collector output: maximum voltage 30 V, maximum current (sink) 8 mA; the status common is floating (isolation voltage or less), it is isolated from the control circuit.