Setting range | Setting item | Description |
---|---|---|
By step | Load value | Current, conductance, voltage, power. The values that can be set depend on the current operation mode. |
Slew rate | Sets the speed of change when the current is changed. | |
Step execution time | 0.000050 s to 3600000 s (50 μs to 1000 h), resolution: 1 μs | |
Load on/off control | To turn the load on, set the load setting transition method to step or ramp. | |
Others | Trigger signal setting, trigger signal output | |
For each program | Number of loops of program | 1 to 100000 repetitions, or infinite repetitions. |
Protection functions | Specifies the value at which a protection function (OCP, OPP, UVP) is activated. |