PCR-LE2_Limit Values and Protection Functions

Item/ModelPCR6000LE2PCR9000LE2PCR12000LE2PCR18000LE2PCR27000LE2
VoltageAC voltage upper limit AC voltage lower limit0.0 V to 305.0 V
DC voltage upper limit DC voltage lower limit-431.0 V to +431.0 V
Output Overvoltage protection AC/AC+DC mode0.0 V to 474.1 V
Output Overvoltage protection DC mode-474.1 V to +474.1 V
Output undervoltage protection AC/AC+DC mode0.0 V to 474.1 V
Output undervoltage protection DC mode-474.1 V to +474.1 V
Resolution0.1 V
Frequencyupper limit lower limit1 Hz to 999.9 Hz, 500 Hz LMT model: 1 Hz to 500 Hz (Three-phase output)
Resolution0.01 Hz (1.00 Hz to 100.0 Hz), 0.1 Hz (100.0 Hz to 999.9 Hz)
CurrentCurrent limit*1 AC modeSingle-phase output6.00A to 66.00A9.00A to 99.00A12.00A to 132.0A18.00A to 198.0A27.00A to 297.0A
Single-phase three-wire output Three-phase output2.00A to 22.00A3.00A to 33.00A4.00A to 44.00A6.00A to 66.00A9.00A to 99.00A
Current limit *1 DC/AC+DC modeSingle-phase output4.20A to 46.20A6.30A to 69.30A8.40A to 92.40A12.60A to 138.6A18.90A to 207.9A
Single-phase three-wire output Three-phase output1.40A to 15.40A2.10A to 23.10A2.80A to 30.80A4.20A to 46.20A6.30A to 69.30A
+Peak Current limit *2Single-phase output6.00A to 264.0A9.00A to 396.0A12.00A to 528.0A18.00A to 792.0A27.00A to 1188A
Single-phase three-wire output Three-phase output2.00A to 88.00A3.00A to 132.0A4.00A to 176.0A6.00A to 264.0A9.00A to 396.0A
-Peak Current limit *2Single-phase output-6.00A to -264.0A-9.00 A to -396.0 A-12.00 A to -528.0 A-18.00 A to -792.0 A-27.00 A to -1188 A
Single-phase three-wire output Three-phase output-2.00A to -88.00A-3.00 A to -132.0 A-4.00 A to -176.0 A-6.00A to -264.0A-9.00 A to -396.0 A
Resolution *30.01 A (0.35 A to 100.0 A) , 0.1A (100.0 A to 1000 A) , 1 A (1000 A to 1188 A)

*1 The actual current value that can be supplied is 1.1 times the Rated current or the Current Limit setting, whichever is smaller. *2 The current that can actually be supplied is the maximum peak current or the current limit, whichever is less. *3 The setting can be made at 0.01A/0.1A/1A, but may not switch between 0.01A/0.1A/1A due to the resolution of the built-in DA.