PCR-LE2_Input ratings (AC rms)

Item/ModelPCR6000LE2PCR9000LE2PCR12000LE2PCR18000LE2PCR27000LE2
3P3W200V3P4W400V3P3W200V3P4W400V3P3W200V3P4W400V3P3W200V3P4W400V3P3W200V3P4W400V
VoltageLine voltage 170 V to 250 VLine voltage 324V to 440V (Phase voltage 187V to 254V)Line voltage 170 V to 250 VLine voltage 324V to 440V (Phase voltage 187V to 254V)Line voltage 170 V to 250 VLine voltage 324V to 440V (Phase voltage 187V to 254V)Line voltage 170 V to 250 VLine voltage 324V to 440V (Phase voltage 187V to 254V)Line voltage 170 V to 250 VLine voltage 324V to 440V (Phase voltage 187V to 254V)
PhaseSingle phaseThree phase 3-wireThree phase 4-wireThree phase 3-wireThree phase 4-wireThree phase 3-wireThree phase 4-wireThree phase 3-wireThree phase 4-wireThree phase 3-wireThree phase 4-wire
Frequency47 Hz to 63 Hz
Apparent powerApprox. 10.6 kVAApprox. 15.7 kVAApprox. 23 kVAApprox. 33 kVAApprox. 48 kVA
Power factor *10.97 (TYP)
Max. currents64 A or less38A or less21A or less55A or less30A or less75A or less39A or less111A or less59A or less165A or less91A or less

*1 When the output phase voltage is 100 V or 200 V, the output current is the rated value, the load power factor is 1, and the output frequency is between 40 Hz and 999.9 Hz.