PCR-LE2_General

Item/ModelPCR6000LE2PCR9000LE2PCR12000LE2PCR18000LE2PCR27000LE2
 3P3W200V3P4W400V3P3W200V3P4W400V3P3W200V3P4W400V3P3W200V3P4W400V3P3W200V3P4W400V
Insulation resistanceBetween input and chassis, output and chassis, input and output500 Vdc, 10 MΩ or more
Withstanding voltageBetween input and chassis, output and chassis, input and output1500 VAC, 1 minute
Circuit methodLinear amplifier system
Environmental conditionsOperating temperature range / Storage temperature range0 °C to +50 °C / -10 °C to +60 °C
Operating humidity range / Storage humidity range20 % rh to 80 % rh (no condensation) / 90 % rh or less (no condensation)
WeightApprox.140 kg (308.6 Ibs)Approx.190kg (418.8 Ibs)Approx.350 kg (771.6 Ibs)Approx.480 kg (1058.2 Ibs)Approx.630 kg (1388.9 Ibs)
Input terminalInput terminal board [3φ]M8M5M5M8M8M8
Output terminalOutput terminal board Single phase · Single phase 3-wire,Three-phase 4-wireM8 · M5M8 · M8
Input power cable [Option sold separately]Typesingle-core cable*Installation (at cost) Attached
The number3 pc4 pc5 pc4 pc5 pc
Conductor cross section/Length14mm2/3m8mm2/3m5.5mm2/3m14mm2/3m5.5mm2/3m
AccessoriesSetup guide1 copy
Quick Reference1 each for English and Japanese
Safety information1 copy
CD-ROM(User’s manual)1 disc
Heavy Duty Warning Seals1 disc
OthersElectromagnetic compatibility (EMC)EMC Directive 2014/30/EU. EN61326-1. EN 55011 The maximum length of all cables and wires connected to the PCR-LE Series must be less than 3 m.
SafetyLow Voltage Directive 2014/35/EU, EN61010-1 (Class I, Pollution Degree2)IEC 61010-1 (Class I, Pollution Degree2)