| Frequency | Resolution | 1μHz |
|---|---|---|
| Amplitude | Range | 10 mVpp to 10 Vpp (50 Ω termination) , 20 mVpp to 20 Vpp (No termination) |
| Accuracy*1*2 | ±1 % of setting ± 1 mVpp (At 1 kHz) | |
| Units | Vpp, Vrms, and dBm | |
| Resolution | 4 digits | |
| DC offset | Range | ±5 V (50 Ω termination), ±10 V (No termination) |
| Accuracy*1*2 | ±2 % of offset setting ±0.5 % of amplitude setting ±2 mV | |
| Resolution | 4 digits | |
| Main Output | Impedance | Typically 50 Ω |
| Isolation | Up to 42 Vpk (From earth) | |
| Protection | Short-circuit protection, overload automatically stops output | |
| Internal frequency reference | Accuracy*2 | ±10 ppm (90 days), ±20 ppm (1 year) |
| External frequency reference input | Lock range | 10 MHz ± 500 Hz |
| Level | 100 mVpp to 5 Vpp | |
| Impedance | Typically 1 kΩ (AC coupled) | |
| Lock time | Less than 2 s | |
| Frequency reference output | Level | Typically 632 mVpp (0 dBm) |
| Impedance | Typically 50 Ω (AC coupled) | |
| Phase offset | Range | -360 ° to +360 ° |
| Resolution | 0.001° | |
| Accuracy | 8ns |