Battery Emulator System_Protection Function LOW Alarm
| Item | BATTERY EMULATOR SYSTEM PXB20K-50 | BATTERY EMULATOR SYSTEM PXB20K-250 | BATTERY EMULATOR SYSTEM PXB20K-500 | BATTERY EMULATOR SYSTEM PXB20K-1000 | BATTERY EMULATOR SYSTEM PXB20K-1500 |
|---|
| OVP (Over Voltage Protection) | Protective operation | Output off, indicate “OVP” on the display. SLV OVP is displayed on the slave unit. |
|---|
| Setting range | 5 V to 55 V | 25 V to 275 V | 50 V to 550 V | 100 V to 1100 V | 150 V to 1650 V |
|---|
| Setting accuracy | ±(0.1 % of setting + 0.2 % of rating) |
|---|
| Resolution | 0.005 V | 0.02 V | 0.05 V | 0.1 V | 0.1 V |
|---|
| OCP (Over Current Protection) | Protective operation | Output off, indicate “OCP” on the display. SLV OCP is displayed on the slave unit. |
|---|
| Setting range (Source) | 80 A to 880 A | 20 A to 220 A | 12 A to 132 A | 6 A to 66 A | 3 A to 33 A |
|---|
| Setting range (Sink) | -80 A to -880 A | -20 A to -220 A | -12 A to -132 A | -6 A to -66 A | -3 A to -33 A |
|---|
| Setting accuracy | ±(0.75 % of rating) |
|---|
| Resolution | 0.1 A | 0.02 A | 0.01 A | 0.005 A | 0.002 A |
|---|
| OPP (Over Power Protection) | Protective operation | Output off, indicate “OPP” on the display. SLV OPP is displayed on the slave unit. |
|---|
| Setting range (Source) | 2 kW to 24 kW |
|---|
| Setting range (Sink) | -2 kW to -24 kW |
|---|
| Setting accuracy | ±(1.0 % of power rating +1.0 % of current rating × Vout) |
|---|
| Resolution | 2 W |
|---|
| UVP (Under Voltage Protection) | Protective operation | Output off, indicate “UVP” on the display. SLV UVP is displayed on the slave unit. |
|---|
| Setting range | 0 V to 50 V | 0 V to 250 V | 0 V to 500 V | 0 V to 1000 V | 0 V to 1500 V |
|---|
| Selectable | Enable/Disable |
|---|
| Setting accuracy | ±(0.1 % of setting + 0.2 % of rating) |
|---|
| Resolution | 0.005 V | 0.02 V | 0.05 V | 0.1 V | 0.1 V |
|---|
| Watchdog Alarm (Communication error protection) | Protective operation | Output off, indicate “WDOG” on the display |
|---|
| Setting range | 1 s to 3600 s |
|---|
| Selectable | Enable/Disable |
|---|
| External Alarm LOW Level (external input alarm detection) | Protective operation | Output off, indicate “EXT LOW” on the display |
|---|