PIA4850
PIA4850
25,000円 (税込:27,500円)
- USB 2.0 compatible
- Can be used with Windows Vista/XP/2000.
- Operates using bus power. Requires no AC adapter.
- Allows read-back of output values and status monitoring.
- Can control up to 32*1 DC power supplies that equip TP-BUS*2. (Different power supply models can be combined.) TP-BUS connection can be extended up to 200 m.
*1 The maximum controlable units are 31 when the connections include PAM series or PMR series unit. *2 TP-BUS (Twist-Pair BUS) is an original Kikusui interface.
Limited stock due to end of production.
カート機能が動くまでの
Specifications
Specifications
Open in a new windowZOOM
Item | Description | |
---|---|---|
TP-BUS | Connections | The connections given below are possible using the provided TP-BUS connector Expansion unit PIA4820: 4 units can be connected (Extension length: Maximum 200 m, Twist count: 1 time/ cm or more) |
Number of controlled units*1 | PAS Series : Maximum 32 units | |
PWR Series : Maximum 32 units | ||
PAM Series : Maximum 31 units | ||
PMR Series : Maximum 31 units | ||
Polarity | None | |
Conforming power wiring | Twisted wire: 0.32 mm2 (AWG22) Extended length: Maximum 200 m 0.20 mm2 (AWG24) Extended length: Maximum 20 m | |
USB | Conforms to USB 2.0 specification. Complies with the USBTMC-USB488 device class specifications Communications speed: 12 Mbps (full speed) (High power device (power consumption: 200 mA) | |
OS(Windows) | 2k (x86, SP4 + Update Rollup 1) XP (x86, SP2 or later) Vista (x86/x64) 7 (x86/x64) 8 (x86/x64) | |
VISA specification | Ver. 3.0 or higher | |
Operating ambient temperature / Humidity range | 0 °C to 40 °C, 10 % rh – 90 % rh (No condensation.) | |
Storage ambient temperature / Humidity range | -20 °C to 70 °C, 10 % rh – 90 % rh (No condensation.) | |
Installation location | Indoors, maximum height 2000 m | |
Safety | Conforms to Low-Voltage Directive 2014/35/EU, EN61010-1 Protection Class I, Pollution Degree 2. | |
Dimensions (maximum) /Weight | 95W x 58D x 18H mm / Approx. 100 g | |
Accessories | USB cable (1 m) TP-BUS connector, TP-BUS cable (1 m) Magnet sheet for bottom fixing CD (user manual, driver files, sample programmes, etc.) |
*1: The maximum controlable units are 31 when the connections include PMR series unit.
Description of Control
Open in a new windowZOOM
Applied Series | PAS | PWR | PAM | PMR |
---|---|---|---|---|
Output voltage setting | ✓ | ✓ | ✓ | ✓ |
Output current setting | ✓ | ✓ | ✓ | ✓ |
Queries the output voltage value | ✓ | ✓ | not controllable | not controllable |
Queries the output current value | ✓ | ✓ | not controllable | not controllable |
Output voltage readback | ✓ | ✓ | ✓ | ✓ |
Output current readback | ✓ | ✓ | ✓ | ✓ |
Designation / Queries of OUTPUT channel number | not controllable | not controllable | not controllable | ✓ |
Designation of output channel number to be displayed | not controllable | not controllable | not controllable | ✓ |
Overvoltage protection startup monitoring setting | ✓ | ✓ | not controllable | not controllable |
Queries the overvoltage protection startup monitoring | ✓ | ✓ | not controllable | not controllable |
Overcurrent protection startup monitoring setting | ✓ | ✓ | not controllable | not controllable |
Queries the overcurrent protection startup monitoring | ✓ | ✓ | not controllable | not controllable |
Output ON / OFF | ✓ | ✓ | ✓ | ✓ |
Power switch OFF | ✓ | ✓ | not controllable | not controllable |
Panel Lock ON / OFF | ✓ | ✓ | ✓ | ✓ |
*For other models (analogue control models), see the PIA4800 series catalogue or contact us separately.
For required drivers and components
Open in a new windowZOOM
Wavy application software | VB、VBA、VC++、LabVIEW | ||
---|---|---|---|
VISA (including USB-TMC driver) | Required | Required | |
PIA4800 instrument driver | IVI-COM/C | Not required | Required in some cases |
IVI Shared Components |
* The latest drivers available at the Kikusui website.
Manual

PIA4850
Updater/Driver

PIA4800 Series/PIA4850 – IVI-COM Multi-Environment Drivers