PIA4850

PIA4850

25,000 (税込:27,500

  • USB 2.0 compatible
  • Can be used with Windows Vista/XP/2000.
  • Operates using bus power. Requires no AC adapter.
  • Allows read-back of output values and status monitoring.
  • Can control up to 32*1 DC power supplies that equip TP-BUS*2. (Different power supply models can be combined.) TP-BUS connection can be extended up to 200 m.

*1 The maximum controlable units are 31 when the connections include PAM series or PMR series unit. *2 TP-BUS (Twist-Pair BUS) is an original Kikusui interface.

Limited stock due to end of production.

カート機能が動くまでの
SKU: PIA4850

Specifications

Specifications

Open in a new windowZOOM

ItemDescription
TP-BUSConnectionsThe connections given below are possible using the provided TP-BUS connector
Expansion unit PIA4820: 4 units can be connected (Extension length: Maximum 200 m, Twist count: 1 time/ cm or more)
Number of controlled units*1PAS Series : Maximum 32 units
PWR Series : Maximum 32 units
PAM Series : Maximum 31 units
PMR Series : Maximum 31 units
PolarityNone
Conforming power wiringTwisted wire: 0.32 mm2 (AWG22) Extended length: Maximum 200 m 0.20 mm2 (AWG24) Extended length: Maximum 20 m
USBConforms to USB 2.0 specification. Complies with the USBTMC-USB488 device class specifications

Communications speed: 12 Mbps (full speed) (High power device (power consumption: 200 mA)

OS(Windows)2k (x86, SP4 + Update Rollup 1) XP (x86, SP2 or later) Vista (x86/x64) 7 (x86/x64) 8 (x86/x64)

VISA specificationVer. 3.0 or higher
Operating ambient temperature / Humidity range0 °C to 40 °C, 10 % rh – 90 % rh (No condensation.)
Storage ambient temperature / Humidity range-20 °C to 70 °C, 10 % rh – 90 % rh (No condensation.)
Installation locationIndoors, maximum height 2000 m
SafetyConforms to Low-Voltage Directive 2014/35/EU, EN61010-1 Protection Class I, Pollution Degree 2.
Dimensions (maximum) /Weight95W x 58D x 18H mm / Approx. 100 g
AccessoriesUSB cable (1 m) TP-BUS connector, TP-BUS cable (1 m) Magnet sheet for bottom fixing CD (user manual, driver files, sample programmes, etc.)

*1: The maximum controlable units are 31 when the connections include PMR series unit.

Description of Control

Open in a new windowZOOM

Applied SeriesPASPWRPAMPMR
Output voltage setting
Output current setting
Queries the output voltage valuenot controllablenot controllable
Queries the output current valuenot controllablenot controllable
Output voltage readback
Output current readback
Designation / Queries of OUTPUT channel numbernot controllablenot controllablenot controllable
Designation of output channel number to be displayednot controllablenot controllablenot controllable
Overvoltage protection startup monitoring settingnot controllablenot controllable
Queries the overvoltage protection startup monitoringnot controllablenot controllable
Overcurrent protection startup monitoring settingnot controllablenot controllable
Queries the overcurrent protection startup monitoringnot controllablenot controllable
Output ON / OFF
Power switch OFFnot controllablenot controllable
Panel Lock ON / OFF

*For other models (analogue control models), see the PIA4800 series catalogue or contact us separately.

For required drivers and components

Open in a new windowZOOM

 Wavy application softwareVB、VBA、VC++、LabVIEW
VISA (including USB-TMC driver)RequiredRequired
PIA4800 instrument driverIVI-COM/CNot requiredRequired in some cases
IVI Shared Components

* The latest drivers available at the Kikusui website.

Manual

Icon
PIA4850
GO TO GLOBAL SITE

Updater/Driver

Icon
PIA4800 Series/PIA4850 – IVI-COM Multi-Environment Drivers
GO TO GLOBAL SITE

Please feel free to contact us with any questions or concerns.