This product has been discontinued.

PLZ164W

PLZ164W

200,000 (税込:220,000

  • Six operating modes are supported (constant current, constant resistance, constant voltage, constant power, constant current + constant voltage, constant resistance + constant voltage)
  • Support of 0-V input (PLZ164WA and PLZ664WA)
  • High-speed response supporting a maximum slew rate of 16 A/µs (equivalent to 10 µs when converted to a rise time)
  • Timer functions combined with time/voltage measurement functions enable battery discharge characteristic evaluations.
  • GPIB/RS232C/USB interface included as standard
  • Equipped with various types of protection circuits: Over Voltage Protection(OVP), Over Current Protection(OCP), Over Power Protection(OPP), Over Heat Protection(OHP), Under Voltage Protection(UVP), And Reverse Connection Protection(REV)

[yith_ywraq_button_quote]

Out of stock

カート機能が動くまでの
SKU: PLZ164W

Specifications

Rating

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating voltage (DC) *1 1.5 V to 150 V *2 0 V to 150 V *3
Current 33A 66A 200A 33A 132A
Power 165W 330W 1000W 165W 660W

*1 Minimum voltage at which the current starts flowing to the PLZ-4W is approximately 0.3 V. For description of theminimum voltage, see “3.3 Operating area of the PLZ-4W”. *2 The minimum operating voltage (including the voltage drop due to the wire inductance component) in switchingmode increases by 0.15 V per 1 A/μs at slew rate settings greater than 5 A/μs. *3 The minimum operating voltage (including the voltage drop due to the wire inductance component) in switchingmode increases by 0.3 V per 1 A/μs at slew rate settings greater than 5 A/μs.


Constant current (CC) mode

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range Range H 0 A to 33 A 0 A to 66 A 0 A to 200 A 0 A to 33 A 0 A to 132 A
M 0 A to 3.3 A 0 A to 6.6 A 0 A to 20 A 0 A to 3.3 A 0 A to 13.2 A
L 0 A to 330 mA 0 A to 660 mA 0 A to 2 A 0 A to 330 mA 0 A to 1.32 A
Setting range Range H 0 A to 34.65 A 0 A to 69.3 A 0 A to 210 A 0 A to 34.65 A 0 A to 138.6 A
M 0 A to 3.465 A 0 A to 6.93 A 0 A to 21 A 0 A to 3.465 A 0 A to 13.86 A
L 0 A to 346.5 mA 0 A to 693 mA 0 A to 2.1 A 0 A to 346.5 mA 0 A to 1.386 A
Resolution Range H 1mA 2mA 10mA 1mA 10mA
M 0.1mA 0.2mA 1mA 0.1mA 1mA
L 0.01mA 0.02mA 0.1mA 0.01mA 0.1mA
Setting accuracy Range H,M ±(0.2% of set+0.1% of f.s *1)+Vin *2/500kΩ
L ±(0.2% of set+0.1% of f.s)
Parallel operation ±(1.2 % of set + 1.1 % of f.s *3)
Input voltage variation *4 Range H 2mA 4mA 10mA 2mA 8mA
M 2mA 4mA 10mA 2mA 8mA
L 0.1mA 0.2mA 0.6mA 0.1mA 0.4mA
Ripple rms *5 3mA 5mA 20 mA *7 7.5mA 30 mA *7
p-p *6 30mA 50mA 100 mA *7 50mA 200 mA *7

*1 Full scale of H range *2 Vin: Input terminal voltage of Electronic Load *3 M range applies to the full scale of H range. *4 When the input voltage is varied from 1.5 V to 150 V at a current of rated power/150 V. *5 Measurement frequency bandwidth: 10 Hz to 1 MHz *6 Measurement frequency bandwidth: 10 Hz to 20 MHz *7 At measurement current of 100 A


Constant resistance (CR) mode

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range *1 Range H 22 S to 400 μS (45.455 mΩ to 2.5 kΩ) 44 S to 800 μS (22.727 mΩ to 1.25 kΩ) 133.332 S to 2.4 mS (7.5 mΩ to 416.666 Ω) 22 S to 400 μS (45.455 mΩ to 2.5 kΩ) 88 S to 1.6 mS (11.363 mΩ to 625 Ω)
M 2.2 S to 40 μS (454.55 mΩ to 25 kΩ) 4.4 S to 80 μS (227.27 mΩ to 12.5 kΩ) 13.3332 S to 2420 μS (75 mΩ to 4.1666 kΩ) 2.2 S to 40 μS (454.55 mΩ to 25 kΩ) 8.8 S to 160 μS (113.63 mΩ to 6.25 kΩ)
L 0.22 S to 4 μS (4.545 5 Ω to 250 kΩ) 0.44 S to 8 μS (2.272 7 Ω to 125 kΩ) 1.33332 S to 24 μS (750 mΩ to 41.666 kΩ) 0.22 S to 4 μS (4.545 5 Ω to 250 kΩ) 0.88 S to 16 μS (1.136 3 mΩ to 62.5 kΩ)
Setting range Range H 23.1 S to 0 S (43.290 mΩ to OPEN) 46.1 S to 0 S (21.692 mΩ to OPEN) 139.9968 S to 0 S (7.1430 mΩ to OPEN) 23.1 S to 0 S (43.290 mΩ to OPEN) 92.4 S to 0 S (10.822 mΩ to OPEN)
M 2.31 S to 0 S (432.9 mΩ to OPEN) 4.61 S to 0 S (216.92 mΩ to OPEN) 13.99968 S to 0 S (71.430 mΩ to OPEN) 2.31 S to 0 S (432.9 mΩ to OPEN) 9.24 S to 0 S (108.22 mΩ to OPEN)
L 0.231 S to 0 S (4.329 Ω to OPEN) 0.461 S to 0 S (2.1692 Ω to OPEN) 1.399968 S to 0 S (714.30 mΩ to OPEN) 0.231 S to 0 S (4.329 Ω to OPEN) 0.924 S to 0 S (1.0822 Ω to OPEN)
Resolution Range H 400μS 800μS 2.424mS 400μS 1.6mS
M 40μS 80μS 242.4μS 40μS 160μS
L 4μS 8μS 24.24μS 4μS 16μS
Setting accuracy *2 Range H,M ±(0.5 % of set *3 + 0.5 % of f.s *4) + Vin *5/ 500 kΩ
L ±(0.5% of set *3 +0.5% of f.s)

*1 Conductance [S] = Input current [A]/ input voltage [V] = 1/resistance [Ω] *2 Converted value at the input current. At the sensing point. *3 set = Vin/Rset *4 Full scale of H range *5 Vin: Input terminal voltage of Electronic Load


Constant voltage (CV) mode

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range Range H 1.5 V to 150 V 0 V to 150 V
L 1.5 V to 15 V 0 V to 15 V
Setting range Range H 0 V to 157.5 V
L 0 V to 15.75 V
Resolution Range H 10mV
L 1mV
Setting accuracy *1 Range H,L ±(0.1% of set+0.1% of f.s)
Input current variation *2 12mV

*1 At the sensing point during remote sensing under the operating range of the input voltage. It is also applied for thecondition of the parrallel operation. *2 With respect to a change in the current of 10 % to 100 % of the rating at an input voltage of 1.5 V (during remotesensing).


Constant power (CP) mode

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operating range Range H 16.5 W to 165 W 33 W to 330 W 100 W to 1000 W 16.5 W to 165 W 66 W to 660 W
M 1.65 W to 16.5 W 3.3 W to 33 W 10 W to 100 W 1.65 W to 16.5 W 6.6 W to 66 W
L 0.165 W to 1.65 W 0.33 W to 3.3 W 1 W to 10 W 0.165 W to 1.65 W 0.66 W to 6.6 W
Setting range Range H 0 W to 173.25 W 0 W to 346.5 W 0 W to 1050 W 0 W to 173.25 W 0 W to 693 W
M 0 W to 17.325 W 0 W to 34.65 W 0 W to 105 W 0 W to 17.325 W 0 W to 69.3 W
L 0 W to 1.7325 W 0 W to 3.465 W 0 W to 10.5 W 0 W to 1.7325 W 0 W to 6.93 W
Resolution Range H 10mW 10mW 100mW 10mW 20mW
M 1mW 1mW 10mW 1mW 2mW
L 0.1mW 0.1mW 1mW 0.1mW 0.2mW
Setting accuracy *1 Range H,M ±(0.6 % of set + 1.4 % of f.s *2)
L ±(0.6 % of set + 1.4 % of f.s *2)

*1 It is not applied for the condition of the parrallel operation. *2 M range applies to the full scale of H range.


Meters

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Voltmeter Range H,M 0.00 V to 150.00 V
L 0.000 V to 15.000 V
Accuracy ±(0.1 % of reading + 0.1 % of f.s)
Ammeter Range H,M 0.000 A to 33.000 A 0.000 A to 66.000 A 0.00 A to 200.00 A 0.000 A to 33.000 A 0.00 A to 132.00 A
L 0.00 A to 330.00 mA 0.00 A to 660.00 mA 0.0000 A to 2.0000 A 0.00 A to 330.00 mA 0.000 A to 1.3200 A
Accuracy ±(0.2 % of reading +0.3 % of f.s)
Wattmeter *1 Range H,M 0.00 W to 165.00 W 0.00 W to 330.00 W 0.0 W to 1000.0 W 0.00 W to 165.00 W 0.00 W to 660.00 W
L*2 0.000 W to 49.500 W 0.000 W to 99.000 W 0.00 W to 300.00 W 0.000 W to 49.500 W 0.000 W to 198.00 W
L*3 0.0000 W to 1.6500 W 0.0000 W to 3.3000 W 0.000 W to 10.000 W 0.0000 W to 1.6500 W 0.0000 W to 6.6000 W

*1 Displays the product of the voltmeter reading and ammeter reading. *2 In a mode other the CP mode *3 In CP mode


Switching mode

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operation mode CC and CR
Duty cycle setting 5 % to 95 % *1, 0.1 % step
Frequency setting range 1 Hz to 20 kHz
Frequency resolution 1 Hz to 10 Hz 0.1Hz
10 Hz to 100 Hz 1Hz
100 Hz to 1 kHz 10Hz
1 kHz to 20 kHz 100Hz
Frequency setting accuracy ±(0.5% of set)

*1 The minimum time width is 10 μs. Between 5 kHz and 20 kHz, the maximum duty cycle is limited by the mini-mum time width.


Slew rate

ZOOM
PLZ164W PLZ164WA Setting range 25 μA/μs to 250 μA/μs 250 μA/μs to 2.5 mA/μs 2.5 mA/μs to 25 mA/μs 25 mA/μs to 250 mA/μs 250 mA/μs to 2.5 A/μs
Resolution 100nA 1μA 10μA 100μA 1mA
PLZ334W Setting range 50 μA/μs to 500 μA/μs 500 μA/μs to 5 mA/μs 5 mA/μs to 50 mA/μs 50 mA/μs to 500 mA/μs 500 mA/μs to 5 A/μs
Resolution 200nA 2μA 20μA 200μA 2mA
PLZ664WA Setting range 100 μA/μs to 1 mA/μs 1 mA/μs to 10 mA/μs 10 mA/μs to 100 mA/μs 100 mA/μs to 1 A/μs 1 A/μs to 10 A/μs
Resolution 400nA 4μA 40μA 400μA 4mA
PLZ1004W Setting range 160 μA/μs to 1.6 mA/μs 1.6 mA/μs to 16 mA/μs 16 mA/μs to 160 mA/μs 160 mA/μs to 1.6 A/μs 1.6 A/μs to 16 A/μs
Resolution 600nA 6μA 60μA 600μA 6mA

Soft start

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Operation mode CC and CR
Time setting range 1, 2, 5, 10, 20, 50, 100, or 200 ms
Time accuracy ±(30% of set+100μs)

Remote sensing

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Voltage that can be compensated 2 V for a single line

Protection functions

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Overvoltage protection (OVP) Turns off the load at 110 % of the rated voltage
Overcurrent protection (OCP) 0.03 A to 36.3 A 0.06 A to 72.6 A 0.2 A to 220 A 0.03 A to 36.3 A 0.13 A to 145.2 A
Or 110 % of the maximum current of each range
Overpower protection (OPP) 0.1 W to 181.5 W 0.3 W to 363 W 1 W to 1100 W 0.1 W to 181.5 W 0.6 W to 726 W
Or 110 % of the maximum power of each range Load off or limit selectable
Overheat protection (OHP) Turns off the load when the heat sink temperature reaches 95 °C
Undervoltage protection (UVP) Turns off the load when detected.
Reverse connection protection (REV) By diode and fuse. Turns off the load when an alarm occurs.

Sequence function

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Normal sequence Operation mode CC, CR, CV, CP
Sequence Maximum number of steps 256
Step execution time 1 ms – 999 h 59 min
Time resolution 1 ms (1 ms – 1 min)/100 ms (1 min – 1 h)/1 s (1 h – 10 h)/ 10 s (10 h – 100 h)/1 min (100 h – 999 h 59 min)
Fast sequence Operation mode CC and CR
Maximum number of steps 1024
Step execution time 25 μs – 100 ms
Time resolution 25 μs (25 μs – 100 μs)/100 μs (100 μs – 100 ms)

Others, Common specifications

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Elapsed time display Measures the time from load on to load off. On/Off selectable.
Measures from 1 s up to 999 h 59 min 59 s
Auto load off timer Automatically turns off the load after a specified time elapses.
Can be set in the range of 1 s to 999 h 59 min 59 s or off
BNC connector Trigger output Trigger output: Approx. 4.5 V, pulse width: Approx. 2 μs, output impedance: Approx. 500 Ω
Outputs a pulse during sequence operation and switching operation.
Current monitor output 1 V f.s (H or L range) and 0.1 V f.s (M range)
Communication function GPIB IEEEstd.488.1-1978
SH1, AH1, T6, L4, SR1, RL1, PP0, DC1, DT1, C0, and E1
Supports the SCPI and IEEE std. 488.2-1992 command set
Sets panel functions except the power switch and reads measured values
RS-232C D-SUB 9-pin connector (conforms to EIA-232-D)
Sets panel functions except the power switch and reads measured values
Supports the SCPI and IEEE std. 488.2-1992 command set
Baud rate: 2400, 4800, 9600, 19200 bps
Data length: 8-bit, Stop bit: 1, 2-bit, Parity bit: None,
Flow control: Xon/Xoff
USB Conforms to USB 2.0 Specifications and USBTMC-USB488 Device Class Specifications
Sets panel functions except the power switch and reads measured values
Communication speed 12 Mbps (Full speed)

General specifications

ZOOM
Model PLZ164W PLZ334W PLZ1004W PLZ164WA PLZ664WA
Input voltage range 100 VAC – 240 VAC (90 VAC – 250 VAC) Single phase, continuous 100 VAC – 120 VAC/200 VAC – 240 VAC (90 VAC – 132 VAC/180 VAC – 250 VAC) Single phase
Input frequency range 47 Hz to 63 Hz
Power 80 VA max 90 VAmax 160 VAmax 300 VAmax 1500 VAmax *1
Inrush current 45 A 80 A
Operating temperature range 0 °C to 40 °C (32 °F to 104 °F)
Operating humidity range 20 % – 85 % RH (without condensation)
Storage temperature range -25°C to 70°C (-13 °F to 158 °F)
Storage humidity range 90 % RH or less (without condensation)
Isolation voltage ± 500 V
Insulation resistance Between primary and input terminals 500 VDC, 30 MΩ or more (ambient humidity of 70 % RH or less)
Between primary and chassis 500 VDC, 30 MΩ or more (ambient humidity of 70 % RH or less)
Withstanding voltage Between primary and input terminals No abnormalities at 1500 VAC for 1 minute.
Between primary and chassis No abnormalities at 1500 VAC for 1 minute.
Weight Approx. 7 kg (15.43 lb) Approx. 8 kg (17.64 lb) Approx. 15 kg (33.1 lb.) Approx. 7.5 kg (16.53 lb) Approx. 16 kg (35.27 lb)
Battery backup Backs up setup information
Accessories Power cord × 1 pc. (with plug, Length: approx. 2.4 m), Load input terminal cover × 1 piece (2 lock plates provided), Set of screws for the load input terminal × 2 sets (bolts, nuts, and spring washers), Setup guide × 1 piece(Japanese, English), Quick Reference(Japanese:1 piece, Englis:1 piece), CD-ROM × 1 piece *2
Electromagnetic compatibility (EMC) *3, *4 Conforms to the requirements of the following standard.
EMC Directive 2014/30/EU
EN 61326-1 (Class A *7), EN 55011 (Class A *7, Group 1 *8), EN 61000-3-2 *9 ,
EN 61000-3-3 *9
Safety *3 Conforms to the requirements of the following standard.
Low Voltage Directive 2014/35/EU *4 EN 61010-1 (Class I *5, Pollution degree 2 *6)

*1. 900 VA when input voltage is 100 VAC. *2. Contains Application & Samples, User’s manual, the Communication Interface Manual and KI-VISA. *3. Does not apply to specially ordered or modified PLZ-4Ws. *4. Limited to products that have the CE mark on their panels. Not be in compliance with EMC limits unless the ferritecore is attached on the cable for connection of J1 connector. *5. This is a Class I equipment. Be sure to ground this product’s protective conductor terminal. The safety of this productis only guaranteed when the product is properly grounded. *6. Pollution is addition of foreign matter (solid, liquid or gaseous) that may produce a reduction of dielectric strength orsurface resistivity. Pollution Degree 2 assumes that only non-conductive pollution will occur except for an occasionaltemporary conductivity caused by condensation. *7. This is a Class A equipment. This product is intended for use in an industrial environment. This product may causeinterference if used in residential areas. Such use must be avoided unless the user takes special measures to reduceelectromagnetic emissions to prevent interference to the reception of radio and television broadcasts. *8. This is a Group 1 equipment. This product does not generate and/ or use intentionally radio-frequency energy, in theform of electromagnetic radiation, inductive and/or capacitive coupling, for the treatment of material or inspection/analysis purpose. *9. Excluding the PLZ664WA.


Dimensions

Lower voltages and higher speeds in semiconductors
Type I (PLZ164W/PLZ164WA/PLZ334W)

Product Catalog

2D CAD

Base view | PDF
Icon

    Operation Manuals

    PLZ_4W
    Icon

      Please feel free to contact us with any questions or concerns.

      Download a Product Catalog View List
      Request a Quotation Contact Us
      close

      Search